User manual

Table Of Contents
Publication No. 980935 Rev. M 3152B User Manual
Astronics Test Systems Programming Reference 5-63
<ampl>
10e
-3 to
16
Numeric
5
Programs the amplitude of the standard sinc waveform
in un
its of Volts.
<offs>
-
7.992 to
7.992
Numeric
0
Programs the offset of the standard sinc waveform in
units of
Volts.
<cycles>
4 to 100
Integer
10
Programs the “0” crossing number of cycles of the
standard sinc waveform in units of percent.
Response
Th
e 3152B returns the current frequency, amplitude, offset, and number of “0” crossing cycles settings
as in
the following example: 1e6,5,0,10.
APPLy:GAUSsian <freq>,<ampl>,<offs>,<exp>(?)
HS Syntax:
0306D<float>,<float,<float>,<integer>(?)
Description
This command
changes the waveform function to standard gaussian and programs
the frequency, amplitude,
offset
,
and exponent simultaneously. This command affects the output regardless of the current output
function. For example, if
the 3152B is in FM mode, the 3152B will stop generating FM and will revert to
the
standard
Gaussian waveform with parametric values as specified by this command.
Parameters
Name
Range
Type
Default
Description
<freq>
10e
-3 to
100e6
Numeric
1e6
Programs the frequency of the standard gaussian
waveform in units of Hz.
<ampl>
10e
-3 to
16
Numeric
5
Programs the amplitude of the standard gaussian
waveform in units of
Volts.
<offs>
-
7.992 to
7.992
Numeric
0
Programs the offset of the standard gaussian waveform
in units of
Volts.
<
exp>
4 to 100
Integer
10
Programs the exponent of the standard gaussian
waveform.
Response
The
3152B returns the current frequency, amplitude, offset and exponent settings as in
the following example:
1e6,5,0,10.
APPLy:EXPonential <freq>,<ampl>,<offs>,<exp>(?)
HS Syntax:
0307D<float>,<float,<float>,<integer>(?)
Description
This command
changes the waveform function to standard exponential and programs
the frequency,
amplitude, offset and exponent simultaneously. This command affects the output regardless of the current
output function. For example, if
the 3152B is in FM mode, the 3152B will stop generating FM and will revert to
the
standard exponential waveform with parametric values as specified by this command.
Parameters
Name
Range
Type
Default
Description
<freq>
10e
-3 to
100e6
Numeric
1e6
Programs the frequency of the standard exponential
waveform in units of Hz.
<ampl>
10e
-3 to
Numeric
5
Programs the amplitude of the standard exponential