OUTPut {OFF|ON|0|1}(?)
HS Syntax: 0200A<0|1>(?)
Description
This command
toggles the 3152B output relay. Note that for safety, the outputs always defaults to off, even if
the last instrument setting before power down was on.
Parameters
Range
Type
Default
Description
0
-1
Discrete
0
Toggles
the output relay between on and off
Response
The 3152B returns 1 if the output is on or 0 if the output is off.
OUTPut:SYNC {OFF|ON|0|1}(?)
HS Syntax:
0240A<0|1>(?)
Description
This command
toggles the 3152B SYNC output. Note that for safety, the SYNC output always defaults to off,
even if the last instrument setting before power down was on.
Parameters
Range
Type
Default
Description
0
-1
Discrete
0
Toggles
the SYNC output between on and off.
Response
The 3152B returns 1 if the SYNC output is on or 0 if the SYNC output is off.
OUTPut:SYNC:POSition<position>(?)
HS Syntax: 0242A<long>(?)
Description
Programs the 3152B SYNC position.
Parameters
Name
Range
Type
Default
Description
<position>
0 to 1e6
-1
Integer
0
Sets
the SYNC position, expressed in waveform po
ints.
The sync position can be programmed in increments of
4 points
(2 points in legacy mode).
The range is
extended to 4e6
-1 when the 4M memory
option is
installed
.
Response
The 3152B returns the current SYNC position value.