4-20 ArbConnection Astronics Test Systems
State
The State button turns on and off the half cycle waveforms function.
The half cycle function can also be selected from the Output panel.
Shape
The Shape group has controls that select the shape of the half
cycle function.
Parameters
The Parameters group has controls for programming the frequency,
amplitude, offset, delay, phase, and duty cycle. Each channe
l can
have an independent set of these parameters.
The Modulation
Panel
s
The five Modulation functions are accessed by clicking the
Modulation header (Figure 4-13)
and then one of the modulation
panels that appear below it. These panels provide access t
o all
modulation functions and their respective parameters. The
modulation functions that are available on these
panels are: FM
(frequency modulation), AM (amplitude modulation), Sweep, ASK
(amplitude shift keying), FSK (frequency shift keying) and PSK
(phase shift keying) and Amplitude and Frequency Hopping.
When modulation run modes other than continuous are selected,
there are two options that control the idle state between triggers: 1)
Carrier baseline and 2) DC baseline. When the first option is
selected, the instrument generates the un-
modulated carrier
frequency (CW) until a valid signal is applied. W
hen the second
option is selected, the instrument generates a DC level signal until
stimulated to generate a modulation cycle. The modulation options,
their associated parameters,
and the various run mode options are
described separately for each of the panels below.
Figure 4-13, Modulation Panels