Specifications

SCPI Command Reference 4-8
Common Commands Parameter Form (Default in Bold) IEEE-STD-488.2
:SMEMory Not Confirmed
:MODE READ | WRITe Not Confirmed
[:STATe] OFF | ON Not Confirmed
:TEST Confirmed
[:ALL]? Confirmed
*CLS Confirmed
*ESE (0;0;255) Confirmed
*OPC Confirmed
*RST Confirmed
*SRE (0;0;255) Confirmed
*TRG Confirmed
*ESE? Confirmed
*ESR? Confirmed
*IDN? Confirmed
*OPC? Confirmed
*SRE? Confirmed
*STB? Confirmed
*TST? Confirmed
Output
Configuration
Command Summary
Output Configuration commands control the output function, shape,
frequency, amplitude, filter and state. Optional modes are omitted
from these commands. Factory defaults after *RST are shown in
bold typeface. Parameter low and high limits are given where
applicable. Use the Standard Waveform parameters as described
in Using The APPLy Command.
Commands and Parameters (Low Limit,High Limit,Default)
[SOURce:]
APPLy:SINusoid {<frequency>,[<amplitude>,[<offset>,[<phase>,[<power>]]]]}
APPLy:TRIangle {<frequency>,[<amplitude>,[<offset>,[<phase>,[<power>]]]]}
APPLy:SQUare {<frequency>,[<amplitude>,[<offset>,[<duty_cycle>]]]}
APPLy:PULSe {<frequency>,[<amplitude>,[<offset>,[<delay>,[<high_time>
,[<rise_time>,[<fall_time>]]]]]]}
APPLy:RAMP {<frequency>,[<amplitude>,[<offset>,[<delay>,[<rise_time>
,[<fall_time>]]]]]}
APPLy:SINC {<frequency>,[<amplitude>,[<offset>,[<number_cycles>]]]}
APPLy:EXPonential {<frequency>,[<amplitude>,[<offset>,[<exponent>]]]}
APPLy:GAUSsian {<frequency>,[<amplitude>,[<offset>,[<exponent>]]]}
APPLy:DC {<percent_amplitude>}
APPLy:USER {<segment_number>,[<sampling_clock>,[<amplitude>,
[<offset>]]]}
APPLy:<function_shape>?
APPLy?
FUNCTion:MODE {FIXed | USER | SEQuence} (FIX)
FUNCTion:MODE?
FUNCtion:SHAPe {SINusoid | TRIangle | SQUare | PULSe | RAMP | SINC
EXPonential | GAUSsian | DC } (SIN)
FUNCtion:SHAPe?
FREQuency {<frequency> | MINimum | MAXimum} (100E-6,50E6,1E6)
FREQuency?
FREQuency:RASTer {<frequency> | MINimum | MAXimum} (100E-3,100E6,1E6)
FREQuency:RASTer?
FREQuency:RASter:SOURce {EXT | INT | ECLtrg0} (INT)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com