Instructions

INSTRUCTIONS
X17™ PA POWER ADJUSTABLE INSTALLATION
RAB Lighting is committed to creating high-quality, aordable, well-designed and energy-ecient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining xture. No user serviceable parts inside.
WARNING: Do not use an electric generator to test LED xtures.
WARNING: Min 75°C SUPPLY CONDUCTORS.
ATTENTION: If the Photocell function is not required, the Shorting Cap (provided) must be installed in place of the Photocell.
SLIPFITTER MOUNT
1. Place the Sliptter over the Tenon and secure the Fixture with
the Screws on the side of the Sliptter as shown in Fig. 1.
2. Make appropriate wire connections per NEC in an approved
enclosure (not included) see Fig. 5.
3. Loosen the Locking Bolt and swivel Fixture to desired angle.
4. Tighten the Locking Bolt.
Fig: 1
TRUNNION MOUNT
To adjust the angle of the Fixture using the Trunnion (Fig. 2):
1. Loosen the Pivot Bolts and Angle Locking Screws.
2. Make appropriate wire connections per NEC in an approved
enclosure (not included) see Fig. 5.
3. Adjust xture to desired angle.
4. Tighten Pivot Bolts and Angle Locking Screw.
X17 PA 450/350/250W Sliptter
X17 PA 450/350/250W Trunnion
Fixture
Sliptter Mount
Wire
Locking Bolt
Support
Fig: 2
Angle Locking Screw
Pivot Bolts