Cut Sheet
VX/ VXBR CFL INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
TROUBLESHOOTING  
1.  Is the proper lamp installed? 
2.  Make sure the lamp is not defective. Try a lamp known to 
be in operating condition.
3.  Check that the line voltage at xture is correct. Refer to 
wiring directions.
4.  Is there voltage at the lamp socket? If there is no voltage, 
check all connections.
5.  Is the xture grounded properly?
ACCESSORIES
Die Cast Guard:    GD100DG
 GD200DG 
Wire Clamp Flat Bottom:  GD100BAR
 GD200BAR
Wire Clamp Round Bottom:  GD100CL 
 GD200CL
REPLACEMEN T  L A M PS  AN D  BALLA ST S 
   RAB Lamp   RAB Ballast 
Wattage   Catalog#     Catalog#   
Compact Fluorescent Lamp
13   LCFL13Q-4P   BCFL13-4E
26   LCFL26   BCFL42
32   LCFL32   BCFL42
42   LCFL42   BCFL42 
LAMP INSTALLATION
CAUTION: Prior to installing, check that the lamp is 
the correct wattage. Observe lamp manufacturer’s 
recommendations on lamp operation, ballast type and 
burning positions.
1.  Disconnect power. Make sure xture and lamp are cool 
enough to touch.
2.  Open xture by unscrewing guard and globe from 
xture.
3.  Fully insert the lamp into the socket.
4.  Replace globe and guard.
5.  Tighten screws.
WIRING
Use supply wire rated for 90°C. The units are wired for 
120V. Units built for a specic voltage are factory-wired 
for the requested voltage. Make sure the supply voltage 
is compatible with the unit. Multi tap units may be used 
with a choice of 120V, 208V, 240V and 277V, provided 
that proper ballast leads are connected in the eld.
1.  Connect the black xture lead to the (+) LINE supply lead.
2.  Connect the white xture lead to the (-) COMMON supply 
lead.
3.  Connect the Ground wire from xture to supply ground.
4.  All unused leads must be capped and insulated.
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool enough to 
touch. Do not clean or maintain while xture is energized.
1.  Clean glass lens with non-abrasive glass cleaning solution.
2.  As lamps age, light output diminishes. Mass re-lamping 
at regular intervals ensures full light output at the highest 
eciency.
Easy Installation & Product Help
Tech Help Line
Call our experts 888 RAB-1000
©2012 RAB LIGHTING Inc.
No
rthvale, New Jersey 07647 USA
rabweb.com
Visit our website for product info
email
Answered promptly sales@rabweb.com
VX/ VXBR CFL-IN 0113
LIGHT
FIXTURE
(+)LINE BLACK
(-)COMMON WHITE
GROUND GROUND
Note: These instructions do not cover all details or variations in 
equipment nor do they provide for every possible situation during 
installation, operation or maintenance.