Instructions

INSTRUCTIONS
SWISH® 2X2, 2X4 INSTALLATION
RAB Lighting is committed to creating high-quality, a ordable, well-designed and energy-e cient LED lighting and controls that make it easy for electricians to install
and end users to save energy. Wed love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing the  xture. No user serviceable parts inside.
RECESSED CEILING MOUNTING
The  xture is suitable only for INDOOR RECESSED CEILING
application. Above ceiling access required.
To mount in an insulated or non-insulated ceiling - 9/16” or 15/16”
exposed Flat Tee Grid Ceiling follow the steps below.
1. Rotate and slide the Housing as required to t through the
Tee-Grid Bar and place it as indicated by the directional arrow
in Fig.1.
2. Firmly bend the pre-installed Grid Clips (4) against the
Tee-Grid Bar to secure the Housing.
3. Support wires are required by Installation Codes. Support the
Housing to the building structure by Support Wires (supplied
by others) through the Support Wire Hole.
4. Make sure that the orientation of the Access Plate faces an
accessible tile to make electrical splices.
5. Loosen screw on Access Plate and remove the Access Plate.
Knock out appropriate Conduit Knockouts on the Access Plate
to route input conduit. Use appropriate conduit connectors as
required by code.
6. Connect wires as shown in wiring diagram. Push all wires back
into the Splice Box. Be careful not to pinch wires.
WARNING: To prevent wiring damage or abrasion, do not expose
wiring to edges of sheet metal or other sharp objects.
7. Replace Access Plate and tighten Access Plate Screw.
8. After installation, remove protective lm from the outer surface
of the lens.
Fig. 1
Tee-Grid Bar
Access Plate
SWISH 2X2 SWISH 2X4
Housing
Grid Clip
Support Wire
(supplied by others)
Support Wire
(supplied by others)
Conduit Knockouts
Firmly bend Grid
Clips against the
Tee-Grid Bar
Tee-Grid Bar
Housing
nominal 4”
Support
Wire Hole
Tee-Grid Bar

Summary of content (3 pages)