Cut Sheet
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
INDEPENDENT TESTING LABORATORIES, INC.
3386 LONGHORN ROAD, BOULDER, CO 80302 USA
PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: itl@itlboulder.com • WEBSITE: www.itlboulder.com
NVLAP LAB CODE: 200925-0
®
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
0 1 2 3 4 5 6 7
2
1
0
1
2
3
4
Transverse Distance in Units of Mounting Heights
ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION
Values based on foot mounting height.
Longitudinal Distance in Units of Mounting Heights
Street Side House Side
IES Cutoff Classification:
Approved
Checked N WHITE
R BEATTIE
Lighting Engineer
2
1
.5
.2
.1
.05
.02
.01
.005
.002
.001
.0005
Full Cutoff
REPORT NUMBER: ITL69105
ISSUE DATE: 07/13/11 PAGE: 1 OF 7
PREPARED FOR: RAB LIGHTING, INC.
CATALOG NUMBER: WPLED10 / WPLED10S /
ALED10 / BLED10
LUMINAIRE: CAST METAL HOUSING, ONE
CIRCUIT BOARD WITH ONE LED CHIP,
FORMED SPECULAR METAL REFLECTOR, CLEAR
FLAT GLASS LENS IN CAST BROWN PAINTED
METAL LENS FRAME.
LAMP: ONE CHIP WITH A 3X3 ARRAY OF
WHITE LIGHT EMITTING DIODES (LEDS) AND
A CLEAR HEMISPHERICAL INTEGRAL LENS,
TILTED 5-DEGREES FROM VERTICAL BASE UP
POSITION.
LED DRIVER: HIGH PERFECTION TECH.
LA1012-12-C1000
NOTE: DATA SHOWN IS ABSOLUTE FOR THE
SAMPLE PROVIDED AT RATED INPUT VOLTAGE
(120VAC, 60Hz) TO THE LED DRIVER.
TOTAL INPUT WATTS = 12.3 AT 120.0
VOLTS
TEST PROCEDURE: IESNA LM-79-08
TEST DISTANCE = 33.25 FEET
10