User Manual

8
2 Picogate Installation
2.1 RequiredItems 
Items included with the G200:
Qty 01, G200 Gateway
Qty 01, 6’ Power supply (corded)
Note: The data service SIM card is pre-installed at the factory.
Additional items required depending on the mounting option selected for each node.
Qty 02, Phillips head sheet rock screws, #10x1”
Option – Velcro tape kit (replacement for sheet rock screw gateway attachment)
Small Phillips head screw driver
Velcro Tape/Tie wraps (optional for cable routing)
2.2 Mounting Location Considerations
1. The G200 gateway must be installed in a secure location and as high as possible for best RF transmission/reception. Attempt
to install sensor nodes as close to the gateway, and as high as possible.
2. Preferred mounting location for the G200 shall be centrally located between the SN400 Sensing Nodes to ensure good signal
reception.
3. To ensure the best signal transmission/reception strength, select an installation location that is free of obstacles that reflect
and absorb radio frequency signals (RF), as well as interference that may distort signals. Avoid installation near or in the
path of strong RF fields. (i.e., computers, microwaves, telecom equipment) and on or near metal objects, air conditioners and
heater ducts since they may cause interference and reduce the G200’s RF performance.
4. Select a location that is not susceptible to drastic temperature changes. A controlled temperature (heating and air-
conditioning) environment is preferred. Also ensure the unit is not exposed to extreme heat or cold so that the enclosure will
not be damaged by external factors (i.e., heat from ovens, cooling racks, exhaust, etc.).
5. Solar loading on the plastic enclosure can heat the electronics inside the case. Avoid mounting locations that are in direct
sunlight at the middle of the day. Mount the gateway under building eaves, or other protected areas.
6. Install the G200 gateway in an “out of the way” location that is not subject to high levels of foot-traffic by people or animals.
Also make sure the G200 does not interfere with usual passage areas by people/employees. Ensure the G200 gateway is
installed in a place that allows easy access for servicing.