User's Manual

TEX100LCD/S
ELETTRONICA
21 / 36
User Manual
Rev. 2.0 - 26/06/19
The bottom line provides instantaneous power reading, press button to increase
level, press to decrease it. When you have achieved the desired level, press
ENTER to confirm and exit the default menu. Please note that the setting is stored
automatically; in other words, if you press ESC or do not press any keys before
the preset time times out, the latest power level set will be retained.
NOTA: This feature prevents the equipment from delivering maximum powerThis feature prevents the equipment from delivering maximum power
as soon as output is enabled from menu 4, or in the event the equipment is
already set to ON when you energise it.
2) Ensure that the equipment is not in a locked-out state. Press ESC to call up
the selection screen (menu 3). Highlight Fnc and press ENTER to confirm and
access the selected menu (menu 4).
If PWR is set to OFF, i.e. power output is disabled, move cursor to PWR. Press
ENTER and label will switch to ON, i.e. power output is enabled.
Press ESC twice to go back to the default menu (menu 1).
3) Fine tune power setting from menu 2 (see description of item 1b) until achieving
the desired value.
WARNING: Equipment is capable of delivering more than rated output power
(100 W for TEX100LCD/S); however, never exceed the specified power
rating.
NOTE: If power is set to 0 W in the Power Setup Menu, the INTERLOCK OUT
contact is activated and any external appliances connected to it are immediately
inhibited.
Next, you can review all operating parameters of the equipment through the
management firmware.
Normally, the equipment can run unattended. Any alarm condition is handled
automatically by the safety system or is signalled by the LED indicators on the
panel or by display messages.
NOTE: Standard factory settings are output power set to upper limit (unless
otherwise specified by customer) and OFF.
5.3 Management Firmware
The equipment features an LCD with two lines by 16 characters that displays a
set of menus. The figure below provides an overview of equipment menus.
The symbols listed below appear in the left portion of the display as appropriate:
(Cursor) - Highlights selected (i.e. accessible) menu.
(Filled arrow) - Editable parameter marker. This symbol appears in menus that
take up more than two lines to aid browsing.