User's Manual

26 / 54
User Manual
Rev. 2.1 - 26/06/19
TEX1002LCD
MenĂ¹ 7
Note that these are readings, rather than settings, and cannot be edited (note the
empty arrow).
VPA Voltage supplied by amplifier module.
IPA Current draw of amplifier module.
Eff Efficiency based on ratio of forward power to amplifier module power,
in percent ( FWD PWR/(Vpa x Ipa) % ).
Tmp Equipment internal temperature reading..
5.3.4 Setup Menu (Set)
This menu lets you view and set operating frequency.
Menu 8
F1 Operating frequency setup. Set a new frequency value and then
press the ENTER button to confirm your selection; the transmitter
unlocks from current frequency (the LOCK LED turns off) and will
lock to the new operating frequency (LOCK turns back on again).
If you press ESC or let the preset time time out, the previous frequency
setting is retained.
5.3.5 Miscellaneous Menu (Mix)
This menu lets you set equipment address in an II
2
C bus serial connection: bus serial connection:
Menu 9