PgD Modifies Power Good threshold for forward power. The Power Good
rate is a percent of equipment rated power (1000W for TEX1002LCD),
not of forward output power. This means that this threshold set at 50%
will give 500 W, respectively, regardless of set power level. The Power
Good feature enables output power control and reporting. When output
power drops below set Power Good threshold, the equipment changes
the state of pin [7] of the DB15 “Remote” connector located on the rear
panel.
PgR Modifies Power Good threshold for reflected power. The Power Good
rate is a percent of equipment rated power (100W for TEX1002LCD),
not of reflected output power. This means that this threshold set at 5%,
respectively, will give 5W regardless of set power level. The Power Good
feature enables output power control and alarm management.
NOTE: This alarm does not trip any contacts in the DB15 “Remote” connector and
is only available in systems equipped with telemetry.
5.3.2 Power Menu ( (Pwr)
This screen holds all readings related to equipment output power:
Menu 6
Fwd Forward power reading.
R Reflected power reading.
Note that these are readings, rather than settings, and cannot be edited (note
the empty triangle). To change power setting, go to the default menu as outlined
earlier.
5.3.3 Power Amplifier (P.A) Menu
This screen is made up of four lines that can be scrolled using the and and
buttons and shows the readings relating to final power stage: