User's Manual
24 / 54
User Manual
Rev. 2.1 - 26/06/19
TEX1002LCD
As soon as operating conditions are restored, power output is re-enabled with the
same settings in use prior to the alarm condition.
Under 20kHz, no modulation occurs. After a preset time of about 5 minutes (not
editable), a NO AUDIO condition is indicated in the main screen, but power is not
inhibited..
State 2
To gain access to a submenu, select menu name (name is highlighted by cursor)
using button
or and press the ENTER button.
To return to the default menu (menu 1), simply press ESC
again..
5.3.1 Operation Menu (Fnc)
In this menu, you can toggle transmitter power output On/Off, set deviation
display mode and the threshold rate for Forward (PgD) or Reflected (PgR)
Power Good.
To edit an item, highlight the appropriate line using the
and buttons and buttons and
then press and hold the ENTER button until the command is accepted. This way,
Pwr setting is toggled between On and Off and Mod setting is toggled between
“x1” and “x10”. To edit the Power Good rate, simply select item “PgD” or “PgR” and
edit its value using the UP and DOWN buttons; finally, press ENTER to confirm.
Menu 5
Pwr Enables (ON) or disables (OFF) transmitter power output.
Mod Modifies modulation display (toggles between “x1” and “x10”). In “x10”
mode, instantaneous deviation indication is multiplied by a factor of 10,
and the bar meter on the default menu will reflect 7.5 kHz instead of
75 kHz. This display mode is convenient when you wish to display low
deviation levels, such as those caused by pilot tone or subcarriers.