User Manual

NOTCHCELL 20W OPERATING MANUAL
R-tron America, Inc. Page: 54 / 57
A.2.4 ALC (Auto Level Control)
This function lets you control ALC settings and the ON/OFF status. To change a setting,
you need to enter a value and click the SET button at the lower part of the Control
Window.
ALC Target : DL output value which you are going to maintain.
Shutdown Target : When repeater DL output value will be over than initial set value,
the repeater will be shutdown.
Shutdown Count : Set the number of shutdown times. When DL output value will be
over than certain value, the repeater will be completely shutdown.
Shutdown On Time : When the repeater output value is over than shutdown target
value, finally it is shutdown. Shutdown on time means repeater re-boot time after
shutdown.
Shutdown Off Time : When output value will be higher than target value, the
repeater will be shutdown again, after spending shutdown off time.
A.2.5 Time Set
When you click the Set button in the window, MCU automatically reads the time of the
PC for time setting. The set time appears on the RTC Time on the SYSTEM window
A.2.6 Reset
This function clears communication status, rebooting the MCU. When you press the
Reset button, current communication status is reset. It leads to MCU rebooting and
then resets the communication status. Then, the information on the current system is
displayed on the screen.