5.5.8 ALC(Auto Level control) & Shut-Down Setting
When you click “ALC” button which is located in left side menu bar, ALC, shutdown
set and ON/OFF control pop-up window will be displayed.
In the pop-up window, you can set downlink path output power like the above 5.5.7.
When DL output value will be over than shutdown target set value, the repeater will
be shutdown.
Normally, shutdown target value will be set 3dB higher than ALC target value.
About how to set shutdown count, shutdown on time and shutdown off time, please
refer it to Appendix A, Chapter A.2.4. ALC.
After input the value, click “SET” button for confirmation which is located in down side
in the ALC Set pop-up window.
Figure 5.15 ALC Set Pop-up Window