User Manual

NOTCHCELL 20W OPERATING MANUAL
R-tron America, Inc. Page: 23 / 57
Figure 3.17 Ground Cable Diagram
3.3.5.3 AC distribution panel grounding
For Surge Protector ground of the AC distribution panel, connect GV 14 cable to the
repeater cabinet grounding cable (GV 38), branching it off with C-Tap (38-14mm).
Connect to the ground Terminal Block in the AC distribution panel with the Fork Type
Terminal Lug.
3.3.6 Installing the feeder cable
3.3.6.1 Installing the feeder cable
1) Connection between the antenna and the repeater
Use two RF Repeater Antennas.
Install a pair of 1/2” cable from the arrestor on the bottom of the repeater cabinet to the
Antenna.
The Standard of feeder cable between the Antenna and the repeater shall be
conformed to that of the carrier.
The Connector for the feeder cable and the connector for the 36mm Æ #36 Flexible
Conduit End Cap are installed on the bottom of the repeater and the RF Antenna.