User Manual
NOTCHCELL 20W OPERATING MANUAL
R-tron America, Inc. Page: 11 / 57
3.3 Installing information
3.3.1 Installation site
3.3.1.1 Right-of-way
- The repeater shall be installed in the location owned or leased by the carrier.
- If the repeater is installed on the roof, spaces for the installation must be considered.
3.3.1.2 Conditions for the Installation space
Installation of the repeater requires the following spaces.
1) Roof
Do not install the repeater near heavy equipments or water tanks for load distribution.
Establishes the repeater in order for the good air circulation of the rear side.
Make sure there is a passage for the equipments to carry the repeater.
2) Field
Select the installation location on a higher ground level to prevent the repeater from
being inundated.
Install the repeater at a distance of at least 5m from the stream or the river.
Make sure there is a passage and parking space for vehicle to carry the repeater.
Install the repeater in where there is no obstacle visually and physically.
Make sure to level the slope when installing on a slope in a mountain area.
3.3.1.3 Precautions
Check the followings before installing the repeater.
1) Roof
Avoid the location in which any accidental or intentional damage may occur.
Do not install the repeater on the weak slab.
Do not install the repeater on the building with the seriously damaged wall.
2) Field
Do not install the repeater on poor ground, sandy soil, or muddy ground.
Do not install the repeater in a ditch, river, or frequently flooded area.
Do not install the repeater on any locations that are easily frozen.
Do not install the repeater near the road.
Make sure to installation after securing safety facilities if installing it near the road.
Do not install the repeater in damp and humid areas.
Take proper measures against salt when installing the repeater in the coast.