goes back to the active status after the ‘Shutdown-on’ time. If the output of the repeater is
higher than the set target value, the repeater will be de-activated again after the set ‘Shutdown-
off’ time.
The repeater repeats the process by the Shutdown count. If the output of the repeater still
exceeds the target value after the repetitive work, the repeater will turn completely off.
Figure 5.18 ALC Setting window
5.3.8.4 Time set
When you press the Time set button at the menu window, the window seen in Figure 5.19 appears.
When you click the Set button in the window, MCU automatically reads the time of the PC for time
setting. The set time appears on the RTC Time on the SYSTEM window [See the Figure 5.8].
Figure 5.19 Time set window
5.3.8.5 Reset
This function clears communication status, rebooting the MCU. When you press the Reset button,
current communication status is reset. It leads to MCU rebooting and then resets the communication
status. Then, the information on the current system is displayed on the screen.