4. Operation
• DL Gain: Type values between 50 and 80 and then click APPLY.
• UL Gain: Type values between 50 and 80 and then click APPLY.
Note
Please make sure DL Automatic Level Control, UL Automatic Level Control
are turned off before the gain setup. Otherwise, it may cause an error.
• DL Automatic Level Control: Type under 30 and then click APPLY and ON.
• UL Automatic Level Control: Type under 30 and then click APPLY and ON.
[Example]
For the repeater with 30dBm Maximum Output power, 80dB Maximum Gain
G%*DLQFRQWUROUDQJHĺ,ILQSXWVLJQDOLV%PDQG$/&LVVHWDVG%P
the gain will be 60dB to adjust to the level.
If input signal is -55dBm, the output power will be 25dBm by the limitation of the
maximum gain even though the ALC is set as 30dBm.
•
Automatic Shutdown: Type the desired values for dBm, seconds and times
and then click APPLY and ON. (e.g. 35 dBm, 3 seconds, 10 times)
[Example]
For the repeater with 30dBm Maximum Output power, 80dB Maximum Gain
/30dB Gain control range, Assuming ASD Level: 35dBm, ASD Time: 3second,
ASD Count: 10.
If the output power is 35dBm (ASD LEVEL) and higher for some reasons, the
repeater will have shut down for 3 seconds (ASD TIME). If this repeats 10 times
(ASD COUNT), the repeater will shut down completely.