User's Manual Part 2

32
4. Operation
Reset To Factory Defaults
- To reset the factory default, click INITIALIZE.
- To restore the previous settings, click RESTORE.
Bandwidth/Frequency:
- For IDEN 800
If you select 18 MHz for bandwidth, the values of the frequency range are
851~869, 850.8~868.8, 850.6~868.6.
If you select 7 MHz for bandwidth, the values of the frequency range is
862~869, 861.8~868.8, 861.6~868.6.
- For IDEN 900
The values of the frequency range is 935~940, 934.8~939.8, 934.6~939.6.
817MHz
18MHz-bandwidth
824MHz806MHz
862MHz
869MHz851MHz 901MHz896MHz
iDEN 800 iDEN 900
940MHz935MHz
7MHz-bandwidth
18MHz-bandwidth 5MHz-bandwidth 5MHz-bandwidth
7MHz-bandwidth
iDEN 800 UL iDEN 800 DL iDEN 900 UL iDEN 900 DLiDEN 800 UL iDEN 800 DL iDEN 900 UL iDEN 900 DL
The Operating Bandwidth and Frequencies of iDEN
Mode
Bandwidth
18MHz-bandwidth
iDEN 800
iDEN 900
Operating Frequency
Downlink
851~ 869MHz
850.8 ~ 868.8MHz
850.6 ~ 868.6MHz
Uplink
806 ~ 824MHz
805.8 ~ 823.8MHz
805.6 ~ 823.6MHz
7MHz-bandwidth
Downlink
862 ~ 869MHz
861.8 ~ 868.8MHz
861.6 ~ 868.6MHz
Uplink
817 ~ 824MHz
816.8 ~ 823.8MHz
816.6 ~ 823.6MHz
5MHz-bandwidth
Downlink
935 ~ 940MHz
934.8 ~ 939.8MHz
934.6 ~ 939.6MHz
Uplink
896 ~ 901MHz
895.8 ~ 900.8MHz
895.6 ~ 900.6MHz