iDEN MINI (RSN-iDEN-30) User’s Manual G G G G R-tron Inc.
RF EXPOSURE INFORMATION The antenna used for this transmitter must not exceed 7dBi and must be installed to provide a minimum separation distance of 22cm from all persons. CAUTION This equipment is indoor use and all the communication wiring are limited to inside of the building.
iDEN MINI G This document describes the specifications, installation and operation of iDEN MINI. Hardware and software mentioned in this document are subject to continuous development and improvement. Consequently, there may be minor discrepancies between the information in the document and the performance and design of the product. Specifications, dimensions and other statements mentioned in this document are subject to change without notice. R-tron Inc.
iDEN MINI G Contents Abbreviations .................................................................................................................... 6G 1.G Introduction ........................................................................................................ 7G 2.G Description .......................................................................................................... 9G 2.1G System Specifications .........................................................................
iDEN MINI G Figures Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure 1.G R-tron iDEN MINI .................................................................................................... 7G 2.G Overview: Service.................................................................................................... 8G 3.G Dimension of iDEN MINI ...............................................................................
iDEN MINI G Abbreviations Abbreviations used in this manual, in iDEN MINI.
iDEN MINI G 1. Introduction Figure 1. R-tron iDEN MINI iDEN MINI repeater is used to fill out areas in iDEN mobile systems, such as base station fringe areas, business and industrial buildings, etc. iDEN MINI receives signals from a base station, amplifies and retransmits the signals to mobile stations. Also it receives, amplifies and retransmits signals in the opposite direction.
iDEN MINI G .G G Figure 2.
iDEN MINI G 2. Description 2.1 System Specifications 2.1.1. Electrical Specifications Parameter Selectable Bandwidth DL & UL 18MHzbandwidth DL 7MHzbandwidth 18MHzbandwidth UL 7MHzbandwidth 5MHzbandwidth Roll off DL & UL Gain ripple Output Power Delay VSWR User’s Manual G In-band BW:18M In-band BW:7.0M In-band BW:5M 851~869MHz 850.8~868.8MHz 850.6~868.6MHz 862~869MHz 861.8~868.8MHz 861.6~868.6MHz 935~940MHz 934.8~939.8MHz 934.6~939.6MHz 806~824MHz 805.8~823.8MHz 805.6~823.6MHz 817~824MHz 816.
iDEN MINI G 2.1.2. Mechanical Specifications Parameter RF connectors Specification N-female x 2, SMA-female x 4 20.87 X 14.01 X 8.66(Inch), 530 X 356 X 220(mm) 24kg (52.912lbs) Size MADE IN KOREA : R-tron lnc. This device complies with Part 15 of the FCC Rules. Operation is subject to the condition tha t this device may not harmful interference. MAKER PRODUCT PART NUMBER : RSN-iDEN-30 POWER : 110 -125V ~ , 60Hz , 4A COMPLIES WITH PART 90, FCC RULES. FCC REG. NO. : STESNiDEN30 SERIAL NO.
iDEN MINI G 2.2 Sub Unit Overview iDEN MINI is composed of the following sub units: UDC(Up Down Converter) HPAs(High Power Amplifiers) Multiplexer Main Control Unit (MCU) Power Supply Unit (PSU) EMI Filter Figure 4.
iDEN MINI G 2.2.1. UDC Module The UDC Module is basically a bi-directional amplifier that sharply filters out unwanted noise. Figure 6.
iDEN MINI G 2.2.2. Multiplexer A multiplexer is a device that combines two or more signals onto a common channel or medium to increase its transmission efficiency. Figure 7.