4. Operation
DL Gain: Type values between 40 and 65 and then click APPLY.
UL Gain: Type values between 40 and 65 and then click APPLY.
Note
Please make sure DL Automatic Level Control, UL Automatic Level Control
are turned off before the gain setup. Otherwise, it may cause an error.
DL Automatic Level Control: Type under 25 and then click APPLY and ON.
UL Automatic Level Control: Type under 25 and then click APPLY and ON.
[Example]
For the repeater with 25dBm Maximum Output power, 65dB Maximum Gain /
20dB Gain control range, If input signal is -35dBm and ALC is set as 25dBm,
the gain will be 60dB to adjust to the level.
If input signal is -45dBm, the output power will be 20dBm by the limitation of the
maximum gain even though the ALC is set as 25dBm.
Automatic Shutdown: Type the desired values for dBm, seconds and times
and then click APPLY and ON. (e.g. 28 dBm, 3 seconds, 10 times)
[Example]
For the repeater with 25dBm Maximum Output power, 65dB Maximum Gain /
20dB Gain control range, Assuming ASD Level: 28dBm, ASD Time: 3seconds,
ASD Count: 10.
If the output power is 28dBm (ASD LEVEL) and higher, the repeater will
shutdown for 3 seconds (ASD TIME). If the shutdown occurs 10 times (ASD
COUNT), the 10th shutdown will be permanent.