User's Manual Part 3

iDEN MINI
User’s Manual -26-
Note 3.
To execute a command, Enter key must be hit.
If the command is successful, OK is displayed but if not, ERROR is displayed.
To reset a MCU (Main Control Unit), type RESET” in.
Examples
1 Frequency Setup
1.1 iDEN 800,
9 Bandwidth: 7MHz
9 Frequency: 861.8MHz ~ 868.8MHz
1.2 iDEN 900 (5MHz fixed bandwidth),
9 Frequency: 934.6MHz ~ 939.6MHz (5MHz-bandwidth)
2 Gain Setup
2.1 iDEN 800
9 TX Gain: 65dB, RX Gain 65dB
2.2 iDEN 900
9 TX Gain: 65dB, RX Gain 65dB
Command: > > 8B 1
> > 8F 1
Command: > > 9F 2
Command: > > 8TG 65
> > 8RG 65
Command: > > 9TG 65
> > 9RG 65
Command: > > RESET