iDEN MI NI Step 5 Execute the Hyper Terminal. Step 6 Name the session and OK. Step 7 Select the TCP/IP (Winsock).
iDEN MI NI Step 8 Set the values as the following and OK. 4.2 Command and Control through the Hyper Terminal Note 1. To see the current status, hit “Enter” key only. Note 2. Type “LIST” and hit “Enter” key to look up the list of commands.
iDEN MI NI Note 3. ▶ To execute a command, “Enter” key must be hit. ▶ I f the command is successful, “OK” is displayed but if not, “ERROR” is displayed. ▶ To reset a MCU (Main Control Unit), type “RESET” in. Command: > > RESET↵ Examples 1 Frequency Setup 1.1 iDEN 800, 9 Bandwidth: 7MHz 9 Frequency: 861.8MHz ~ 868.8MHz Command: > > 8B 1↵ > > 8F 1↵ 1.2 iDEN 900 (5MHz f ixed bandwidth), 9 Frequency: 934.6MHz ~ 939.6MHz (5MHz-bandwidth) Command: > > 9F 2↵ 2 Gain Setup 2.
iDEN MI NI 3 ALC (Automatic Level Control) Level Setup: 18dBm Command: > > TXALC_LEVEL 18↵ > > TXALC ON↵ 4 Command: > > RXALC_LEVEL 18↵ > > RXALC ON↵ ASD* (Automatic Shut Down) Setup: 9 Level: 30dBm, Time: 3sec, Count: 10 * I f the output power gets higher than “Level”, the repeater will shut down for “Delay” time and then turn on the amp and measure the output power again. I f this repeats “Count” times, the repeater will shut down completely.
iDEN MI NI The maximum output power for operating is +25 dBm on both Tx and Rx.
iDEN MI NI * Reference The Operating Bandwidth & Frequencies Bandwidth 18MHz-bandwidth iDEN 800 7MHz-bandwidth iDEN 900 5MHz-bandwidth Operating Frequency 851~869MHz Downlink 850.8~868.8MHz 850.6~868.6MHz 806~824MHz Uplink 805.8~823.8MHz 805.6~823.6MHz 862~869MHz Downlink 861.8~868.8MHz 861.6~868.6MHz 817~824MHz Uplink 816.8~823.8MHz 816.6~823.6MHz 935~940MHz Downlink 934.8~939.8MHz 934.6~939.6MHz 896~901MHz Uplink 895.8~900.8MHz 895.6~900.
iDEN MI NI 5. Troubleshooting 5.1 RF Connection Check Problem Either the downlink output power or the uplink output power (=Input Power to the repeater) is too weak. Solution Check if the following RF connections are loose: 1. The cable connection from the donor antenna to the donor antenna port 2. The cable connection from the service antenna port to the service antenna 5.2 Power Connection Problem All LEDs at the bottom are turned off. Figure 17.
iDEN MI NI Figure 18. AC power cord Check 5.3 Red Light on the Alarm LED Problem Red light LED turns on the Alarm LED after applying AC power. Figure 19. Red Light on Alarm LED Solution Request a technical support.
iDEN MI NI iDEN MINI Copyright © R-tron Inc. 2000-2007 All Rights Reserved 6042, College Boulevard, Overland Park, KS 66211 Any reproduction, distribution, or revision of any or all portions of this manual is prohibited without written permission from R-tron Inc. The information in this guide is subject to change without any prior notification. www.r-tron.