User's Manual

RV-QUADCOMM USERS MANUAL V1.0.00 Tech Support: 1-888-317-8766
26
4.B. Manual Gain Setting
When you want to set gain value not using Auto Gain control refer to the following;
Step 1. For manual gain control AGC must be turned off
(700M, 1900M, 2100M : 30dBm / 800M : 25dBm)
Step 2. The user can select any gain value as long as it does not over-drive the amplifier or exceed isolation
requirements. Gain is automatically limited where conditions do not permit high gain. Select the DL
and UL Gain values. Turn on the DL and UL path controls
Result 1 DL and UL gain are fixed and the output power depends on the input power
Result 2 Maximum DL Output Power 30dBm
If the DL Input Power >= -57dBm and the isolation value is ≥max gain+15dB