User Manual

System Description NOTCHCELL Repeater
R-TRON Proprietary & Confidential Page 29
It should be as most as possible near with power input/output port, and Wires do so that to do not become
overlap each other.
Also, must do so that high frequency resistance may minimize in grounding paper as possible when do
mounting to Repeater.
When fix EMI/EMC Filter to metal case for this, after improving electricity conductibility removing coats of paint
of contact part, do to ground in the nearest distance coming ground connection terminal.
In case of use continuously exceeding rating current or use exceeding operating temperature, its performance
and reliability are fallen.
Specification
Item Specification Remarks
Rated Voltage 250V AC/DC
Rated Current 20A
Rated Frequency 50/60Hz
Leakage Current 0.75Ma max. at 250V AC 50/60Hz
Insulation Resistance
200M
min. AT 500V DC
Test Voltage AC 2000V between line to earth for 1 minute
Operating Temperature
-25
~ +85
5.11 Heater Module
Figure 28 Block diagram of Heater Module
Heater Module attached inside Main Box and PSU Box for normal action of equipment in limit low temperature
state because Repeater's operating temperature condition is '- 40 to -55
'.
Specification
Item Specification Remarks
Input Power AC100V +/-20% 50/60Hz +/-5%
Current 5A max.