G Easy Setup is a fast start function. The function measures isolation, detects input level and
assing gain to achieve maximum output power. The function ends with the repeater set to
amplify siganals in both directions within the confines of the band selection. Before running
easy setup, set the center frequency and bandwidth (refer 5.5.4).
G Isolatoin Check can be executed at anytime to measure isolation between the donor and
server antennas. Isolation Check momentarily disables service. Isolation check automatically
runs when factory default is initiated.
G Factory Default restores the amplifier to its initial state. The function ends with amplifiers off,
AGC mode off, gain set to minimum(55dB) and UL gain offset set to 0dB. Band sellection and
all other system parameters are not changed. The featurs is usefull in claering abnormal
conditions.
G System Reset cycles the microporcessor unit. The function is similar to switching off/on the
repeater power switch.