• Location Information: Enter the latitude and longitude. You can input values either in
Decimal Degrees or Degrees-Minutes-Seconds.
[Example]
(‘N/S’ | ‘E/W’) ddd.dddddd: (Latitude: N 39.006967 Longitude: W 94.532306)
• Refresh Time: Set each refresh time for connecting to Local port and Remote port.
¾ ETHERNET SETTING
• Ethernet IP Mode/IP Address: Enables you to set a connection mode for the network
connected to the APEX8930 remote LAN port. When you “select” Auto, the device
automatically assigns the IP address. When you select “Static”, You will enter the device
IP address.
• SNMP: In order to send Heartbeat and alarm related information to a remote monitoring
server, you can set a server IP address. The factory default IP address is 10.22.25.15.
• Heartbeat Interval: Sets the time to transmit the Heartbeat to the NMC Server.
(Default value is 20 minutes.)
User Note
<User Note>
• Location Information: Type the location information such as the building name, address, city,
state, zip code and telephone, and then click Apply.
G Donor Site Information: Type the base station ID. Click Apply.
G Installer Information: Type the installer information such as the company, name and telephone,
Click Apply.