User's Manual
APEX730 USER MANUAL V1.0.00 Tech Support: 1-888-317-8766
32
5. Troubleshooting
Before contacting your service dealer, refer to the following guidelines. If the APEX730 repeater
does not work normally after completing the following troubleshooting, please contact your
local dealer or R-tron America’s Tech support line (1-888-31R-TRON).
External alarm lamps on the front of the repeater indicate current condition. Green lamp
indicates power to the repeater, yellow indicates caution, and red indicates shut sown
5.1 LED Alarm
Problem Check Point Solution
Critical PWR LED is Flicking Power supply out of range
- Confirm AC 110 - 220V common use power
and power cable.
TD LED is red Tamper detected
- Front Cover open 상태인지 확인한다.
BTF LED is red Built-in test failure
- Web GUI alarm 상태를 통하여 아래 알람 중
어느 알람이 발생하였는 지 확인한다.
- UL Out-of-band emissions, DL Spurious
emissions, DL Interferer power exceeded, DL
Low isolation, Over temperature
- Case 2) When Alarm indicator 으로 문제 해결
RMF LED is red Replaceable module failure
- reset Repeater’s power
- Repeater’s alarm LED is still red,
Contact
Technical Support
OSC LED is red Oscillation detected
- Donor / Server ant. Isolation을 확인하여
Gain+15dB 이하인 경우 ant 위치 조정을 하여
Isolation을 확보한다.
SD LED is red Shutdown
- Web GUI를 이용하여 S/D reason을 확인한다.
- Manual HPA Off인 경우 다시 On 시킨다.
- Overpower S/D이 발생하고, Manual Gain 설
정 상태인 경우 Gain 설정을 적절하게 낮춘다.
- Overpower S/D이 발생하고, ALC 기능이On되
어 있는 경우 ALC Level을 1~3dB 낮게 설정
하고 장시간 모니터링한 후 이상이 없으면
확정한다. (본 증상은 Input Power 변화가 심
한 환경에서 발생할 수 있음)
Minor DCF LED is orange Donor Circuitry failure
- DL Donor Power too high
- 중계기 입력으로 들어오는 DL input Power를
확인한 후 중계기 허용치 이상일 경우 외부
Atten을 달거나 ant 위치를 조정하여 허용치
이내로 들어오게 한다.
DPL LED is orange Donor power too low
- DL Donor Power too low
- 중계기 입력으로 들어오는 DL input Power가