User's Manual
APEX1933 USER MANUAL V1.2 Tech Support: 1-888-317-8766
24
• Easy Setup is a fast start function. The function measures Isolation, detects input level and
assign gain to achieve maximum output power. The function ends with the equipment set
to amplify signals in both directions within the confines of the band selection. Before
running easy setup, set the center frequency and bandwidth (refer to 4.3.3 part 2).
Maximum DL output power requires at least -10dBm input power and sufficient antenna
isolation.
• Isolation Check can be executed at anytime to measure isolation between the donor and
server antennas. Isolation Check momentarily disables service. Isolation check automatically
runs when factory default is initiated.
• Factory Default restores the amplifier to its initial state. The function ends with amplifiers
off, AGC mode off, gain set to minimum(15dB) and UL gain offset set to 0dB. Band selection
and all other system parameters are not changed. The featurs is usefull in claering abnormal
conditions.
• System Reset cycles the microprocessor unit. The function is similar to switching off/on the
equipment power switch.
5.5.2 Operating Control
• DL and UL Path Control allows the user to toggle on or off the power amplifiers.
• DL and UL Gain is available when AGC mode is off. The user may enter gain values
manually. Manual gain control is an alternative to automatic gain control (AGC). Manual
gain is disabled (grayed out) when AGC mode is on. Gain cannot be controlled manually
above the available gain found on the status page. The system will not allow gain to be
increased such that maximum output power (33dBm) is exceeded.