Instruction manual

11
Never lubricate the cylinder valve with oil or grease.
Never allow an electrode to touch a cylinder!
Do not expose cylinders to excessive heat, sparks, molten
slag or flames.
Do not tamper with the cylinder valve.
Do not try to loosen tight valves by means of a hammer,
a wrench, or any other object.
B) PRESSURE REGULATORS
Keep pressure regulators in good condition. Damaged
regulators may cause damages or accidents. They should
be repaired by skilled personnel only.
Do not use regulators for gases other than those for which
they were manufactured.
Never use a leaking or damaged regulator.
Never lubricate regulators with oil or grease.
C) HOSES
Replace hoses which appear to be damaged.
Keep hoses unwound in order to prevent kinks.
Keep the excess hose neatly wound and out of the working
area in order to avoid damage.
Cylinder fittings should never be modified or exchanged.
1.2.5 Radiation
Ultra-violet radiation emitted by arc rays may
damage your eyes and burn you skin. Therefore:
Wear proper clothing and helmet.
Do not use contact lenses!! The intense heat created
by the arc may cause them to stick to the cornea.
Use a mask or helmet equipped with lens shades that have
a minimum DIN rating of 10
Warn people in the area surrounding the welding sight that
you are going to be welding.
Remember: the arc may dazzle or damage the eyes. It is
considered dangerous up to a distance of 15 meters (50
feet). Never look at an arc with the naked eye.
Prepare the welding area so as to reduce the reflection
and transmission of ultra-violet radiation: paint walls and
exposed surfaces in black to reduce reflection, install
shielding systems or curtains to reduce the transmission
of ultra-violet rays.
Replace protective lenses whenever damaged or broken.
1.2.6 Electric shock
Electric shocks are hazardous and potentially fatall!!
Do not touch live electrical parts.
Insulate yourself from the workpiece and the
ground by wearing insulated gloves and clothing.
Keep garments (gloves, shoes, hats, clothing) and body
dry.
Do not work in humid or wet areas.
If you are welding near a body of water take precautions
to ensure that the machine cannot fall into the water.
Avoid touching or holding the workpiece by hand.
Should you work in a dangerous area or close to one , use
all possible precautions.
Stop welding immediately if you should feel even the
slightest sensation of electric shock. Do not use the
machine until the problem is identified and corrected.
Often inspect the mains input cable.
Disconnect the power input cable from the mains supply
before replacing cables or before removing the unit covers.
Do not use the unit without protection covers.
Always replace any damaged parts withGENUINECEBORA
SPARE PARTS.
Never disconnect any of the unit's safety devices.
Make sure that the mains power supply line is equipped
with a good electrical ground.
Servicing of the machine must be done by qualified
personnel who aware of the risks involved with the high
voltage levels necessary to make the machine operate.
1.2.7 Pacemaker
Magnetic fields created by the high currents in the weld
circuit can affect pacemaker operation. Persons wearing
electronic life support equipment (pacemakers) should
consult their doctor before going near any arc welding,
gouging, cutting, or spot welding equipment in operation.
1.2.8 Noise
These power sources alone do not produce noise levels
exceeding 80 dB. The AC TIG welding procedure,
however, may produce noise levels in excess of 80
dB in which case the machine take operator must
take the necessary safety precations as prescribed
by the national take safety regulations.
2 GENERAL TECHNICAL DESCRIPTIONS
2.1 SPECIFICATIONS
These machine are constant current power sources, suitable
for both the TIG and Manual Metal Arc welding procedures.
These technologically advanced, high quality power sources
incorporate, single current adjustment range, square wave
technology and total central of the welding current.
Upon receiving and unpacking the machine, make a careful
inspection to ensure that there are no damaged parts. Should
there be a claim for losses or damages it must be made by the
purchaser directly to the shipper who handled the goods.
When requesting information about this welding machine
please state the machine’s part number and serial
number to ensure receiving accurate information relating
to your machine.
2.2 DESCRIPTION OF TECHNICAL SPECIFICATIONS
U
0
V
-
U
0
V
-
X-- -
X-- -
U
2
---
U
2
---
I
2
-- -
I
2
-- -
-/---/-
-/---/-
1
PROTEZIONE TERMICA
THERMAL PROTECTION
PROTECTION THERMIQUE
TERMISCH GESCHÜTZ
PROTECCION TERMICA
VENTILAZIONE FORZATA
FORCED VENTILATION
VENTILE
KUHLART F
VENTILACION
IP 21
EN 60 974-1
U
1
V
-
-
-
-
-
-
I
1
A
-
-
-
-
-
-
I
1
A
-
-
-
-
-
-
I
1
A
-
-
-
-
-
-
I
1
1
~
50/60
Hz
I. Cl.