Instruction manual

-- 7 --
bt33d1ea
Recommend ed fuse sizes and minimum cable area
Tig 2200i AC/DC TIG MMA
Mains voltage 230 V ¦10 %,1μ 230 V ¦10 %,1μ
Mains frequency 50 Hz 50 Hz
Mains cable area mm
2
3G2,5 3G2,5
Phase current IRMS 14 A 15.3 A
Fuse
anti--surge
type C MCB
16 A
16 A
16 A
16 A
NOTE!The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. Use the welding power source in accordance with the relevant national regulations.
6 OPERATION
General safety regulations for the handling of the equipment can be found on
page 3. Read through before you start using the equipment!
6.1 Connections and control devices
1 Connection for remote control unit 6 Connection for return cable
2 Control panel (see separate instruction
manual)
7 Mains switch
3 Connection for torch 8 Mains cable
4 Connection for gas to the torch 9 Connection for shielding gas
5 Connection for welding cable or torch
GB