Installation guide

D-17
Catalogue numbers
and order forms
To indicate your choices, check the applicable square
boxes
and enter the appropriate information in the
rectangles .
(one sheet per device, make copies if necessary)
Indication contacts
OF - ON/OFF indication contacts
Standard 4 OF 6 A-240 V AC (10 A-240 V AC and low-level for NW)
Additional 1 block of 4 OF for NW max. 2
qty
Device identication:
EF - combined “connected/closed” contacts
Q 1 - NORMAL SOURCE
1 EF 6 A-240 V AC for NW max. 8
qty
Q 2 - REPLACEMENT SOURCE
1 EF low-level for NW max. 8
qty
Circuit breaker or switch-disconnector
SDE - “fault-trip” indication contact
Masterpact type NT
NW Standard 1 SDE 6 A-240 V AC
Rating A
Additional 1 SDE 6 A-240 V AC 1 SDE Low level
Sensor rating A Programmable contacts 2 M2C contacts 6 M6C contacts
Circuit breaker N1, H1, H2, H3, L1 Carriage switches 6 A-240 V AC Low level
Switch-disconnector NA, HA, HF, ES,
HA10 (NW)
CE - “connected” position max. 3 for NW / NT
qty
CD - “disconnected” position max. 3 for NW, 2 for NT
qty
Number of poles 3 or 4 CT - “test” position max. 3 for NW, 1 for NT
qty
Option: neutral on right side AC - NW actuator for 6 CE - 3 CD - 0 CT additionnal carriage switches
qty
Device Fixed
Remote operation
Withdr. chassis Remote ON/OFF MCH - gear motor
V
Withdr. without chassis
(moving part only)
XF - closing voltage release
V
MX - opening voltage release
V
Chassis alone without connections PF - “ready to close” contact Low level
Micrologic control unit
6 A-240 V AC
A - ammeter BPFE - electrical closing pushbutton
2.0
5.0 6.0 7.0 Res - electrical reset option
V
P - power meter 5.0 6.0 7.0 RAR - automatic reset option
H - harmonic meter 5.0 6.0 7.0 Remote tripping MN - undervoltage release
V
AD - external power-supply module
V
R - delay unit (non-adjustable)
TCE - external sensor (CT) for neutral protection Rr - adjustable delay unit
Rectangular sensor
for earth-leakage protection
NT
(280 x 115 mm)
2
nd
MX - shunt release
V
NW (470 x 160 mm)
Locking
LR - long-time rating plug Standard 0.4 to 1 Ir VBP - ON/OFF pushbutton locking (by transparent cover + padlocks)
Low setting 0.4 to 0.8 Ir OFF position locking:
High setting 0.8 to 1 Ir
VCPO - by padlocks
LT OFF VSPO - by keylocks Keylock kit (w/o keylock) Profalux Ronis
PTE - external voltage measurement input (required for
reverse supply)
Kirk Castell
1 keylock Profalux Ronis
BAT - battery module 2 identical keylocks, 1 key Profalux Ronis
Communication
2 keylocks, different keys (NW) Profalux Ronis
Eco COM module Modbus Chassis locking in “disconnected” position:
(for switchboard display units) VSPD - by keylocks Keylock kit (w/o keylock) Profalux
Ronis
Connections
Kirk Castell
Horizontal Top Bottom 1 keylock Profalux Ronis
Vertical Top Bottom 2 identical keylocks, 1 key Profalux Ronis
Front Top Bottom 2 keylocks, different keys Profalux Ronis
Vertical-connection adapters NT - FC xed, draw. Optional connected/disconnected/test position locking
Cable-lug adapters NT - FC xed, draw. VPEC - door interlock On right-hand side of chassis
Arc chute screen NT - FC xed On left-hand side of chassis
Interphase barriers NT, NW xed, draw. VPOC - racking interlock
Spreaders NT xed, drawout IPA - cable-type door interlock
Disconnectable front
connection adapter
NW xed IBPO - racking interlock between crank and OFF pushbutton for NW
DAE - automatic spring discharge before breaker removal for NW
Lugs for 240
v
or 300
v
cables NT xed, draw. VDC - mismatch protection
VO - safety shutters on
chassis
NT, NW
X
Accessories
CDM - mechanical operation counter
VIVC - shutter position
indication and locking
NW CB - auxiliary terminal shield for chassis
CDP - escutcheon
CP - transparent cover for escutcheon
OP - blanking plate for escutcheon
Brackets for mounting NW xed on backplates
Test kits Mini test kit Portable test kit
Source-changeover systems
for 2 devices
Masterpact NT or NW / Circuit breakers
and switch-disconnectors
Livre 1.indb 17 08/10/2008 18:40:47