Specifications

Rated Output Current 130Amps Max
Generator required KVA 4.8KVA
Duty Cycle @ 130 AMPS
35% @ 40
ºC
Duty Cycle @ 100 AMPS
60% @ 40
ºC
Duty Cycle @ 75 AMPS
100% @ 40
ºC
Output current Range 30-130 AMPS
No Load Voltage 55-75V
Gross Weight 18 KG
Insulation Class F
Safety Precautions
Read entire section before starting installation
WARNING!
Electric Shock can kill – Only qualified personnel should perform this installation. Turn off input
power at the fuse box before working on this equipment. Do not touch electrically live parts.
Always connect the machine to an earthed mains supply as per national recommended
standards.
Select suitable location
Place the welder where clean cooling air can freely circulate in and out of the front & rear louver
vents. Dirt, dust or any foreign material that can be drawn through vents into welder must be kept
to a minimum. Failure to observe these precautions can result in excessive operating
temperatures which can lead to plant failure.
Grinding
Do not direct grinding particles towards the welder. An abundance of conductive material can
cause plant failure.
Stacking
This machine cannot be stacked. Transport – Unloading
Never underestimate the weight of equipment, never move or leave suspended in the air above
people. Use recommended lifting equipment at all times.