Read old values
from old unit
Description Last recording
Value []
Estimated increase
since last record
Copy value to Set Value
1-1-4 Cycles Counter how often a load bigger than 20% of
hoist nominal load was lifted
7-1 Cycles
1-1-7 MFI1 RT Run time in hours from Multi Function Input 1 7-2 MFI1 RT
1-1-8 MFI1 ST Start counter from Multi Function Input 1 7-3 MFI1 ST
1-1-9 MFI2 RT Run time in hours from Multi Function Input 2 7-4 MFI2 RT
1-1-10 MFI2 ST Start counter from Multi Function Input 2 7-5 MFI2 ST
2-2 RT slow Hoist run time in hours with slow speed. 7-6 RT slow
2-3 RT fast Hoist run time in hours with slow speed 7-7 RT fast
2-4 No. OT Counter for hoisting motor over temperatures 7-8 No. OT
2-5 No OL Counter value for overload situations 7-9 No OL
2-6 E-stops Counter for emergency stops 7-10 E-stops
2-7 ST up Counter value for UP requests 7-11 ST up
2-8 ST down Counter value for DOWN requests 7-12 ST down
2-9 ST fast Counter value for FAST requests 7-13 ST fast
2-10 Max ED Max value of calculated ED percentage 7-14 Max ED
2-11 Over ED Minutes when the ED value has exceeded the
designed values.
7-15 Over ED
2-13 SRT3 Calculated value from Load and Run time, ^ 3 7-16 SRT3
2-14 SRT8 Calculated value from Load and Run time, ^8 7-17 SRT8
2-16 SL1 Calculated value from Load and Cycles, ^1 7-18 SL1
2-17 SL3 Calculated value from Load and Cycles, ^3 7-19 SL3
2-18 SL8 Calculated value from Load and Cycles, ^8 7-20 SL8
2-19 Power on Total hours when the unit was powered on. 7-21 Power on must be 0
2-20 Temp index Power on time weighted with unit’s temperature.
7-22 Temp index must be 0
2-21 Max Load The highest measured load. 7-23 Max Load
6-18 Max Br Max designed brake operations.
1-1-6 Br SWP% Counter of Stops and E-Stops
7-24 Brake operation
counter
If only Monitor 1-Condition monitoring menu’s values are read, some parameter values are possible
to calculate to menu 7.
Description Read old values
from old unit
Set value
Desing
values from
parameter
7-1 Cycles Counter how often a load bigger then 30% of
hoist nominal load was lifted
1-1-4 Cycles Set the parameter’s 1-1-4 Cycles value
7-2 MFI1 RT Run time in hours from Multi Function Input 1 1-1-7 MFI1 RT Set the parameters 1-1-7 MFI1 RT value
7-3 MFI1 ST Start counter from Multi Function Input 1 1-1-8 MFI1 ST Set the parameter’s 1-1-8 MFI1 ST value
7-4 MFI2 RT Run time in hours from Multi Function Input 2 1-1-9 MFI2 RT Set the parameters 1-1-9 MFI2 RT value
7-5 MFI2 ST Start counter from Multi Function Input 2 1-1-10 MFI2 ST Set the parameter’s 1-1-10 MFI2 ST value
7-6 RT slow Hoist run time in hours with slow speed. 1-1-3 Run time
25,0*__ timeRunslowRT =
7-7 RT fast Hoist run time in hours with slow speed 1-1-3 Run time
75,0*__ timeRunfastRT =
7-8 No. OT Counter for hoisting motor over temperatures Set to 0
7-9 No OL Counter value for overload situations Set to 0
7-10 E-stops Counter for emergency stops Set to 0
7-11 ST up Counter value for UP requests 1-1-2 Starts
5,0*_ StartsupST =
7-12 ST down Counter value for DOWN requests 1-1-2 Starts
5,0*_ StartsdownST =
7-13 ST fast Counter value for FAST requests 1-1-2 Starts
75,0*_ StartsfastST =
7-14 Max ED Max value of calculated ED percentage Set to 0
7-15 Over ED Minutes when the ED value has exceeded the
designed values.
Set to 0
7-16 SRT3 Calculated value from Load and Run time, ^ 3 1-1-1 SWP%
3_*
%100
%
3 SRTD
SWP
SRT =
6-10
D_SRT3
7-17 SRT8 Calculated value from Load and Run time, ^8 Set to 0