Owner manual

R&M Materials Handling, Inc.
4501 Gateway Boulevard
Springfield, Ohio 45502
P.: (937) 328-5100
FAX: (937) 325-5319
102/105
R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.
Example drawing
FG
N.C.
G2
V2
G1
V1
0 VDC
24 VDC
12 VDC
WRM-22FWX-U+
GND
ON
OL
20 5
4
ROUT
RIN
11
12
1
2
3
4
5
6
AC L
7
AC N
8
10VDC AIN1 AIN2 AIN3 IB 0VDC
ANALOG INPUT
@ANALOG INPUT
25 26 27 28 29 30
135
24678910.11.12.13.14.15.
GN
YE
BU RD
Off
0V -IN 10V + IN SH
10V
SIGN
0V
LOAD SENSOR
K1K2K3
N
18VAC
LOAD INDICATOR UNIT ESD143
0V
Signal
+ 10V
Shield
OUT+
OUT-
IN- IN+
OL00
ON
OL00
ON
A-A1
A-T10
A-A1
A-A4
A-B1
A-A3
Settings of the external power supply
Voltage output V1 can be adjusted with a trimmer. In our applications voltage must be set to 11,00-11,50
VDC.
V1 voltage adjust trimmer: set to 11.00-11,50 VDC
Power supply with cover plate Power supply without cover plate