User Manual

LM TMU I&M MANUAL/EN/06.15.2009
20/38
This document and the information contained herein, is the exclusive property of R&M Materials Handling, Inc., and represents a non-public, confidential and proprietary trade secret
that may not be reproduced, disclosed to third parties, altered or otherwise employed in any manner whatsoever without the express written consent of R&M Materials Handling, Inc.
Copyright © (2009) R&M Materials Handling, Inc. All rights reserved.
3.10 Trouble Shooting – Brake
3.10.1 Compact Brake
The Compact brake is used on the MF06 inverter motor only.
Brake will not release:
y Air gap too large adjust air gap
y Presence of foreign matter clean brake
y Check Motor Parameter setting consult Section 4.2.3
Insufficient braking torque:
y Grease on lining replace lining
y Damaged lining replace lining
y Air gap too large adjust air gap
y Worn friction material replace lining
3.10.2 D.C. Disc Brake
The D.C. Disc brake is used on the two-speed motor only.
Brake will not release:
y Presence of foreign matter clean brake
y Bad rectifier replace rectifier
Insufficient braking torque:
y Grease on lining replace lining
y Damaged lining replace lining
y Air gap too large replace friction material
y Worn friction material replace friction material