7.5.4 Control methods
Table 7. Three different control methods:
1
EP
Electronic potentiometer function.
Stepless control using a 2-step controller.
2
MS
Multistep control (2 steps)
Requires programmable digital inputs for speed reference steps
3
AU
Automation control for any control device with an output in the range of 0
10V
E.g. radio controls, process computers.
All control methods are available without any changes in the hardware or software.
The control mode is selected by parameter P1.1.11 Input set. The parameter assigns digital inputs S1, S2
and DID3-DID5. It is not possible to change the functions of the inputs separately. The state of inputs can be
checked from parameter V2.3.
Table 8. Control Modes
Control Mode
MS2
(stop-lim)
EP2
(stop-lim)
AU (Ain1) Must not
be used
Parameter P1.1.11 0 2 7 1,3,4,5,6
Signal Terminal
S1 DID1 S1 S1 S1 -
S2 DID2 S2 S2 S2 -
DID3 DID3 MAX AP S11/S21 -
DID4 DID4 S12 S12 S12 -
DID5 DID5 S22 S22 S22 -
S1 Drive command direction S1 S2 Drive command direction S2
AP Acceleration command MAX Maximum frequency
S12 Stop-limit forward S22 Stop-limit reverse
S11/S21 Common slowdown limit
Table 9. Desired speed levels for multi-step control mode are selected with following parameters
Speed Parameter Input
Minimum P1.1.4 S1/S2
Maximum P1.1.5 MAX