Owner`s manual
8
REV 4 0811041514
No. L-A2-02908
EMBER PLACEMENT
Sprinkle embers lightly and evenly over entire surface
of the granules. (When using with Charred Series log
sets, refer to pages 10 - 11). Replace the grate so that
the bottom tabs on the log-locator brackets fi t over the
back edge of the pan, locking it in position.
The Peterson Real-Fyre gas log set must be installed by an NFI Certifi ed or other qualifi ed, professional installer.
Instructions must be followed carefully to insure proper performance and full benefi t from your gas log set.
Peterson Real-Fyre gas logs must be installed only
in a wood burning fi replace with the minimum venting
requirements met (see Page 3). Check parts list to
be sure all parts are included. Gas supply pipe must
be l/2" minimum interior diameter or larger. If the gas
line is longer than 20', a larger diameter line may be
necessary.
REFER TO PARTS LIST (PAGE 4) WHEN
FOLLOWING THESE INSTRUCTIONS.
INSTALLATION OF BURNER
(be sure gas to the fi replace is off)
1. Remove the grate from the carton and attach
the log locators to the
2 outer bars of the
grate with bolts and
nuts. The log locators
should be positioned at
the middle of the bars
with bolt slots facing
towards fi replace side
walls (Figure 1). Do not
tighten until after Step
4.
2. Connect the burner pan to the regulator inlet.
Attach the smaller adaptor from the CK-5 kit to
the end of the nipple behind the regulator on
your manual, or 15 valve and tighten. For the 01
valve connect it to the brass elbow at the rear of
the valve.
3. Place the burner assembly into the fi replace so
the open burner pan faces to the room.
4. Place the grate over the burner pan so the log
locator brackets fi t over the back edge of the
burner pan to lock it in position. Tighten the log
locators into place.
5. Center this assembly in the fi replace and place it
as far back in the fi replace as possible. Remove
the grate for gas connection and granule
placement.
6. Connect the larger adaptor from the CK-5 kit
(Item 15a) to the gas supply and tighten. Using
the CK-5 kit tubing, connect the gas supply to
the small CK-5 elbow on the regulator or elbow
(installed in step 2). Ensure the pan rests level
on the fi replace fl oor after connection. Adjust the
pan if necessary.
7. Turn on the gas to the fi replace and test for leaks
with soapy water solution. (Never use open
fl ame for testing).
8. Place the heat shield over the valve and
regulator.
IMPORTANT: THE HEAT SHIELDS MUST BE
IN PLACE DURING OPERATION
OF THE GAS LOG SET.
OVERHEATING OF THE VALVE
WILL CAUSE SHUT DOWN
OF GAS LOG SET OR OTHER
OPERATING PROBLEMS.
INSTALLATION OF YOUR GAS LOG SET
GRANULE PLACEMENT
With the burner off and the grate removed, fi ll the
burner pan completely with granules*. Slope the
granules at the same angle as burner pan.
*NOTE: Use only select sand for natural gas burners
and vermiculite for propane gas burners.
GRANULE AND EMBER PLACEMENT
NOTE: For 15 valve units, the decorative wood
chunk is placed in front of valve for
decorative purposes only.
Figure 1
Important For all valves, the air MUST be purged from the gas line before the pilot will light properly.
The time taken to do this will depend on the length of gas line from the meter to the unit and
the length of time since the unit or gas line was last used (in the case of non-use during warm
weather for example). It may take from 3-10 minutes before all the air is purged and the pilot
will light properly. To do this use the method used for lighting the pilot, which varies depending
on which valve is fi tted to the unit. Follow the lighting instructions in this manual for method.