Owner`s manual
3
REV 4 0811041514
No. L-A2-02908
IMPORTANT INFORMATION
Do not use this log set if any part has been under
water. Immediately call a qualified, professional
service technician to inspect the appliance and to
replace any part of the control system and any gas
control which has been under water.
The gas log set must be isolated from the gas supply
piping system by closing its individual shut-off valve
during any pressure testing of the gas supply system
at test pressures equal to or less than 1/2 psig. The
gas log set and its individual shut-off valve must be
disconnected from the gas supply piping system when
testing at pressures in excess of 1/2 psig.
Keep the area of the gas log set clear and free from
combustible materials, gasoline and other fl ammable
vapors and liquids.
MAINTENANCE: Periodically remove the logs and
examine the burner assembly. If dirty, clean with a stiff
brush. Also examine the area around burner and pilot.
Any dirt or lint in this area should be removed. This
will ensure long life and trouble-free operation.
An annual inspection and cleaning of the vent system
by a qualifi ed agency is recommended.
IMPORTANT: For safe operation and proper
performance and to comply with CSA Certifi cation,
ONLY Robert H. Peterson parts and accessories
must be used with this gas log set.
The minimum inlet gas supply pressure for purpose
of input adjustment is 5" for natural gas and 10" for
propane gas. Maximum inlet gas supply pressure for
this burner is 10.5" for natural and 13" for propane
gas.
A fi replace screen must be in place when the log set
is burning and, unless other provisions for combustion
air are provided, the screen shall have an opening(s)
for introduction of combustion air. When a glass
fi replace enclosure (door) is used, operate the gas
log set with the glass doors open.
The minimum fi rebox dimensions in which log set is
certifi ed to be installed, is listed in the Technical Data
Table below.
Your Real-Fyre Gas Log Set has been certifi ed to the
following standards:
ANSI Z21-60b-2004
CSA 2.26-2004
15' 24 SQ" 36 SQ" 46 SQ" 49 SQ" 35 SQ" 46 SQ" 54 SQ" 58 SQ"
20' 21 SQ" 29 SQ" 38 SQ" 41 SQ" 32 SQ" 43 SQ" 49 SQ" 52 SQ"
25' 17 SQ" 26 SQ" 32 SQ" 35 SQ" - - - -
30' 16 SQ" 23 SQ" 29 SQ" 31 SQ" 29 SQ" 39 SQ" 45 SQ" 47 SQ"
Chimney
Height
16" 18"&20" 24" 30"&36" 16" 18"&20" 24" 30"& 36"
Minimum Free Opening Area of Chimney Damper for Venting
For Masonry Built Fireplaces
Log Set Sizes
For Factory Built Fireplaces
Log Set Sizes
NOTE: The minimum chimney height from hearth to top of chimney is 15'.
NOTE:
FOR REMOTE READY
UNITS, THE
MAXIMUM BTU
THRU PUT OF SOME
VALVES MAY VARY
Burner
Size Front Opening * Depth Height Nat. Propane
16" 26" 13" 18" 55,000 35,000
18"/20" 30" 13" 18" 75,000 45,000
24" 34" 14" 18" 90,000 65,000
30" 40" 14" 18" 96,000 75,000
36" 46" 14" 18" 96,000 75,000
Real-Fyre G5 Series Technical Data Table
BTU Rating
Minimum Fire Box Dimensions
*
An additional 2"/3" is recommended to center the log set.
THE FOLLOWING LOG STYLES ARE
NOT
COMPATIBLE WITH THE G5 BURNER SYSTEM:
Royal English Oak Designer (BD), Heritage Oak Designer (HD), Charred Royal English Oak (CHB),
Royal English Oak (B), Heritage Oak (H), Mountain Oak (K), Driftwood (D).
ALL OTHER R. H. PETERSON LOG STYLES ARE COMPATIBLE.
CONSULT YOUR LOCAL REAL FYRE DEALER FOR A DEFINITIVE LIST