1. Turn off all electric power to warm air circulator or remote control system if service is to be performed.
2. Place remote or switch in 'OFF' position. Turn variable fl ame control to 'OFF'. The pilot will remain lit.
3. If complete shutdown is desired, remove the "RADIANT HEAT SHIELD". Push in the ignitor knob and
turn clockwise to the 'OFF' position. Replace the "radiant heat shield".
1. LIGHTING - turn
all knobs to 'OFF'
and wait 5 minutes
before lighting.
1. STOP Read the safety information above.
2. Turn 'OFF' any electrical appliance (such as the
Peterson warm air circulator or any remote control
system) if used with the log set.
3. Remove the "RADIANT HEAT SHIELD".
4. Push in ignitor control knob, turn clockwise to
'OFF' position (Figure 21). Turn variable fl ame height
control clockwise to 'OFF' position.
5. Wait fi ve (5) minutes to clear out any gas. If you
then smell gas, STOP! FOLLOW "1" in the safety
information above. If you don't smell gas, go to the
next step.
6. Locate the pilot. Follow the metal tube from the gas
control. Pilot is located at the right rear of burner
pan.
7. To light pilot, turn ignitor knob, from 'OFF' position,
clockwise towards 'IGN' until reaching stop. Press
ignitor knob in and hold for 5 seconds (only pilot gas
will fl ow).
8. Continue holding knob in, turn the ignitor control knob
to 'PILOT' to activate the piezo ignitor (you should
hear a click, pilot should light). Continue to hold ignitor
knob in for 30 seconds after pilot is lit. Release ignitor
knob and it will pop back up. The pilot should remain
lit. If it goes out, repeat steps 5 through 8.
• If the knob does not pop up when released, stop
and immediately call your service technician
or gas supplier.
• If the pilot will not stay lit after several tries,
turn the gas control knob to 'OFF' and call
yourservice technician or gas supplier.
9. Turn ignitor knob counterclockwise to 'ON'.
10. With the pilot lit, turn the fl ame height control towards
'ON' (counterclockwise). to desired fl ame height
and heat output.
Replace the "Radiant Heat Shield"
11. If an electrical appliance is used with the log set, turn
on or reconnect that appliance.
Note: If the pilot should extinguish or you would like to
manually turn off the valve see step #3 below.
* We recommend that before you install your log set you familiarize yourself with the control valve layout. This will
help you to be confi dent operating the log set when fully installed (see Figures below for typical control positions).
2. Turn Dial to
'IGN', push in and turn
to 'PILOT' position.
Press knob in and hold
for 60 seconds while
lighting pilot.
OFF PILOT ON
Figure 21
TO TURN OFF THE GAS LOG SET
3. Turn knob
to 'ON'. To light
burner turn Variable
Flame Height Knob
towards 'ON'
1. Use 'OFF'
when complete
shutdown is
desired.
FOR YOUR SAFETY, READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fi re or explosion may
result causing property damage, personal injury or loss of life.
The Peterson Real-Fyre gas log set has a pilot which
must be lit by hand. When lighting the pilot, follow these
instructions exactly.
1. BEFORE LIGHTING, smell all around the gas log
set area for gas. Be sure to smell next to the fl oor
because some gas is heavier than air and will settle
on the fl oor.
WHAT TO DO IF YOU SMELL GAS
• Open a window.
• Do not try to light the appliance.
• Do not touch any electrical switch, do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fi re
department.
2. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it. Call a qualifi ed,
professional service technician. Force or attempted
repair may result in fi re or explosion.
3. Do not use the gas log set if any part has been under
water. Immediately call a qualifi ed, professional service
technician to inspect the gas log set and to replace any
part of the control system and any gas control which
has been under water.
LIGHTING INSTRUCTIONS 15(P) VALVE
If this unit was shipped with a remote, or if a remote system was installed later, read and follow the separate
remote instructions to operate the burner remotely.