Owner`s manual
13
REV 4 0811041514
No. L-A2-02908
TO TURN OFF THE GAS LOG SET
1. From the 'ON' position, turn the control knob clockwise to the 'PILOT' position. The log set will
extinguish and the pilot will remain lit.
2. If complete shutdown is desired, from the 'PILOT' position, push in the control knob slightly and turn
clockwise to the 'OFF' position. Do not force the knob.
3. Wait fi ve (5) minutes to clear out any gas. If you
then smell gas, STOP! Follow "1" in the safety
information above. If you don't smell gas, go to
the next step.
4. Find pilot - follow the metal
tube from the gas control. The
pilot is above the burner tube
behind the front log.
5. Turn the knob on the gas
control counterclockwise
to'PILOT'.
6. Push in the control knob all the
way and hold in. Immediately
light the pilot with a longneck butane lighter or a
long match. Continue to hold the control knob in
for approximately one (1) minute after the pilot
is lit. Release the knob and it will pop back out.
The pilot should remain lit. If it goes out, repeat
steps 3 through 6.
*If the knob does not pop out when released, stop and
immediately call your service technician or gas supplier.
*If the pilot will not stay lit after several tries, turn the
gas control knob to 'OFF' and call your service
technician or gas supplier.
7. Turn gas control knob counterclockwise to
'ON' to light your set. The main burner will ignite
at the maximum BTU's.
8. Periodically check the pilot fl ame (Figure 20) for
proper fl ame pattern.
LIGHTING INSTRUCTIONS FOR G5 MANUAL
1. BEFORE LIGHTING, smell all around the gas
log set area for gas. Be sure to smell next to
the fl oor because some gas is heavier than air
and will settle on the fl oor.
WHAT TO DO IF YOU SMELL GAS
• Open a window.
• Do not try to light the appliance.
• Do not touch any electrical switch, do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fi re department.
2. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, don't try to repair it. Call a
qualifi ed, professional service technician. Force or
attempted repair may result in fi re or explosion.
3. Do not use the gas log set if any part has
been under water. Immediately call a qualifi ed,
professional service technician to inspect the
gas log set and to replace any part of the control
system and any gas control which has been under
water.
1. STOP! Read the safety information above.
2. Push in the gas control knob slightly and turn
clockwise to 'OFF' (Figure 19). NOTE: The
knob cannot be turned from 'PILOT' to 'OFF' unless
the knob is pushed in slightly. Do not force.
WARNING:
If you do not follow these instructions exactly, a fi re or explosion may result causing property
damage, personal injury or loss of life. The Peterson Real-Fyre gas log set has a pilot which must be lit
by hand. When lighting the pilot, follow these instructions exactly.
Figure 20
2. Turn Dial to 'PILOT'
position. With match
ready press knob in and
hold for 60 seconds
while lighting pilot.
3. Turn knob to 'ON'
to light burner.
1. Use 'OFF'
only when com-
plete shutdown is
necessary.
OFF PILOT ON
1. LIGHTING - turn
knob to 'OFF'
and wait 5 minutes
before lighting.
Figure 19
* We recommend that before you install your log set you familiarize yourself with the control valve layout. This will
help you to be confi dent operating the log set when fully installed (see Figures below for typical control positions).
FOR YOUR SAFETY, READ BEFORE LIGHTING