Owner`s manual
10
INSTALLATION (Cont.)
Fig. 10-1
Gas supply
Flare adaptor
Flex connector
(coming from
valve assy)
CONNECT TO THE GAS SUPPLY
1. Bring the gas-supply pipe up from beneath the unit near
its center.
Note: Locate the gas supply line out of pathways where
people may trip over it or in areas where the line may
be subject to accidental damage.
2. Install the supplied fl are adaptor to the gas supply (NPT)
using a gas pipe sealing compound or Tefl on tape (see
Fig. 10-1).
3. Connect the flex connector coming from the valve
assembly to the gas supply adaptor (see Fig. 10-1).
CONNECT TO A POWER SUPPLY (05 Series Only)
Connect the power supply coming from the control panel to a
110V GFI receptacle (not included). Reference the illustration
on the previous page.
LEAK TEST
Turn on the gas supply, ignite the burner, and test at all
connections for leaks using a soapy water solution. If bubbles
appear, a leak is present. Turn off the gas and tighten at all
connections. Repeat until no leaks are present. If a leak
persists, turn off the gas supply and contact the local gas
company or dealer. NEVER USE A FLAME TO CHECK FOR
LEAKS.
CONTROL PANEL INTERIOR ACCESS (IF APPLICABLE)
If access to the interior of the control panel is required (for
servicing), follow the instructions below:
1. The control panel bottom plate must be removed to allow
access to the transformer / valve assembly found inside.
Remove the screws found along the bottom of the control
panel sides (see Fig.10-2).
Note: There are 2-3 screws found on the bottom of each
side.
2. When service is completed, reposition the control panel
bottom plate in place and fasten using the existing screw.
Fig. 10-2