Owner`s manual

12
CONNECTING THE GAS TO THE OUTDOOR CAMPFYRE
(Cont.)
Place the Outdoor Campfyre
enclosure at the installation location over the gas-supply pipe. The
supply pipe should not protrude more than 3" up into the enclosure. Ensure the fl ex connector does
not become kinked or damaged. Do not allow the unit to rest on it.
FOR 05 SERIES MODELS; the controls must be within reach of a 110V GFI receptacle (for the
power supply).
If using propane gas, it is recommended that the supply tank be set a minimum of 10' from the
Outdoor Campfyre
. Use black steel pipe for the supply pipe, with a shutoff valve in line before the
Outdoor Campfyre
.
1. Remove the four (4) retaining screws from the burner pan assembly (Fig. 12-1).
2. Carefully lift pan assembly (Fig. 12-2 or 12-3), allowing access to center of fi re pit and fl ex connector
kit. Attach fl ex connec tor kit to main gas-supply line using Tefl on tape or pipe compound resistant to
propane gas. Tighten connections.
Fig. 12-1
Figure 4.
CAREFULLY LIFT BURNER ASSEMBLY FROM THE ENCLOSURE TO ACCESS GAS CONNECTION
POINT AT VALVE. BE CAREFUL NOT TO DETACH ANY WIRES OR DAMAGE GAS LINES.
Fig.12-3 Remote unit shown
Fig. 12-2 Manual unit shown
GAS LINE
IN
LINE FROM
VALVE TO
BURNER
PILOT GAS LINE
Line from
valve to
burner
Gas line
in
Pilot gas line
Note: The procedure is the same for all valve types.
Line from
valve to
burner
Pilot gas line
Burner
pan
Burner pan
retaining screw
holes (4)
ACCESSING THE GAS CONTROL SYSTEM
01 model
shown
Unscrew
to lift pan
assembly