Owner`s manual

11
BE CAREFUL
If not installed and used correctly per these instructions,
this product can cause serious injury.
CAUTION: Installation and maintenance must be done by an NFI Certifi ed or other qualifi ed professional
installer. Read these instructions before installing this Outdoor Campfyre
. Be sure you understand
all safety precautions and warnings contained in this manual.
A. FOR OUTDOOR USE ONLY. THIS UNIT MUST BE INSTALLED AT LEAST 36" FROM ANY COMBUSTIBLE
WALLS OR MATERIAL. IT MUST NOT BE INSTALLED UNDER ANY TYPE OF CEILING OR OVERHANG
(SEE FIG. 11-1).
B. When shutting the unit down—be sure to TURN THE CONTROL VALVE FULLY OFF.
C. WARNING: CARBON MONOXIDE POISONING MAY LEAD TO DEATH. DO NOT MODIFY THIS OUTDOOR
CAMPFYRE
OR ITS CONTROLS, EXCEPT AS PROVIDED FOR IN THIS MANUAL. Any other change
may be dangerous. Improper installation or use of the Outdoor Campfyre
can cause serious injury or death
from fi re, burns, explosions, or carbon monoxide poisoning.
D. Check state and local codes to determine if the Outdoor Campfyre
is permitted in your locality before
installation.
IMPORTANT SAFETY INFORMATION
The dimensions shown in Fig. 11-1 are MINIMUM
CLEARANCES to maintain when you install this
Outdoor Campfyre
. ALL SIDES of the enclosure
opening MUST BE AT LEAST 36" from any
combustible side walls. The unit MUST NOT BE
installed under any type of ceiling or overhang.
Clearances to Combustible Construction:
Side walls: 36" from edge of top ring (Fig. 11-1).
Ceiling: Nothing should be above the Outdoor
Campfyre
.
Flooring: 0" - Can be installed on deck, slab, fl oor, etc.
MINIMUM CLEARANCE TO COMBUSTIBLES
Tools Required:
1. Adjustable open-ended wrench
2. Pliers
3. Pipe compound resistant to all gas or Tefl on tape
4. Soapy water solution & brush for leak detection
5. Phillips-head screwdriver
6. Manometer (recommended for checking gas pressure)
BEFORE PROCEEDING, CAREFULLY READ ALL OF THE IMPORTANT SAFETY INFORMATION
CONTAINED IN THIS OWNER’S MANUAL, INCLUDING:
A. PRE-INSTALLATION AND OUTDOOR CAMPFYRE
PREPARATION SAFETY GUIDELINES.
B. INSTALLATION SAFETY GUIDELINES.
C. MINIMUM CLEARANCE TO COMBUSTIBLES.
Installation and maintenance must be done by an NFI Certifi ed or other qualifi ed professional installer.
Installer: Read these instructions before installing this Outdoor Campfyre
. Be sure you understand
all safety precautions and warnings contained in this manual.
BE SURE THE GAS SUPPLY FOR THE OUTDOOR CAMPFYRE
IS TURNED OFF.
Note: To install the Peterson Outdoor Campfyre
, you must have a gas-supply line that has been installed
by a qualifi ed professional technician in accordance with all local codes. Refer to the PARTS LIST
when installing the Outdoor Campfyre
.
CONNECTING THE GAS TO THE OUTDOOR CAMPFYRE
36
CLEARANCE
FROM SIDES
TO ANY
COMBUSTIBLE
CONSTRUCTION
36
CLEARANCE
NOTE:
NOTHING SHOULD BE
ABOVE THE OUTDOOR
CAMPFYRE.
FROM SIDES
TO ANY
COMBUSTIBLE
CONSTRUCTION
Fig. 11-1
Note: Nothing should be above
the Outdoor Campfyre
.
36"
Clearance
36"
Clearance
From sides to
any combustible
construction
From sides to
any combustible
construction
Important: Be sure you have read and understand all safety precautions and warnings contained in this
manual.