Note: Pilot fl ame should encircle top of the generator.
Lighting the Pilot
To light the pilot, make sure the toggle switch is
in the OFF (DOWN) position. Rotate the safety
valve knob pointer counterclockwise to the PILOT
position. Push the safety valve knob fully in and at
the same time place a long match or a butane lighter
at the pilot burner. The pilot will light. Hold the safety
valve knob in for approximately 60 seconds. If the
pilot does not stay lit, turn the safety valve knob to
the OFF position. Wait fi ve minutes and repeat the
lighting instructions. If the pilot still fails to stay lit
see the Troubleshooting section.
Lighting and Extinguishing the Burner System
To turn on your gas log set with the pilot lit, turn
the safety valve knob to the ON position. Switch the
toggle switch control to the on (UP) position and
the gas log set will light.
To turn off your gas log set, switch the toggle
switch control to the off (DOWN) position. The pilot
will remain lit. See the instructions that came with
the remote kit (if purchased) for remote lighting
instructions.
To turn off the pilot, be sure the toggle switch
control is off (DOWN) and depress and turn the
safety valve knob to the OFF position.
Maintaining the Pilot
Your log set is equipped with a safety pilot that
will shut off the gas supply in case the pilot is not
burning or functioning properly. Verify that the
generator spade clips are tightly connected to
the terminal screws on the valve and the pilot is
adjusted properly with the pilot fl ame hitting the
generator as shown in Fig. 10-2 If the pilot will not
stay lit, call your local gas utility or gas supplier.
Cleaning and Checking
A periodic check of the following should be
performed at least annually by a qualified
professional service representative.
1. Proper operation of valves and switches.
2. Flue system for proper venting.
3. Damper operation
4. Orifi ces for dirt or other foreign matter.
5. Visual check on the burner.
6. Air mixers for dust/lint blockage.
7. Excessive soot on logs.
Lighting and Operating Instructions
Safety Pilot System
The Real-Fyre burner system has a pilot which can be lit by hand using a match or lighter. When lighting the pilot, follow
these instructions exactly.
BEFORE LIGHTING, smell all around the burner area for gas. Be sure to smell next to the fl oor as some gas is heavier than
air and will settle on the fl oor. IF YOU SMELL GAS, FOLLOW THE INSTRUCTIONS ON THE COVER (P. 1).
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing
property damage, personal injury or loss of life.
Do not use this appliance if any part has been underwater. Immediately call for a qualifi ed professional
service technician to inspect the appliance and to replace any part of the control system and any gas control
which has been under water.
FOR YOUR SAFETY, READ BEFORE LIGHTING
Fig. 10-1
Fig. 10-2
Lighting
the Pilot
TOGGLE
SWITCH
PILOT
BURNER
IN
WIRING
HARNESS
PILOT
GAS SUPPLY
PILOT
GENERATOR
PILOT CAP
SCREW
PILOT
GAS PORT
SAFETY
VA LVE
CONTROL
KNOB
TH
TP
TH
TP
JUMPER
WIRE
24" models
30" - 60" models