Owner`s manual
14
INSTALLATION (Cont.)
Fig. 14-4
Anchoring holes are provided to bolt
the burner to the fi replace fl oor.
REFER TO THE BURNER PARTS LIST WHEN FOLLOWING
THESE INSTRUCTIONS.
1. MAKE SURE THE FIREPLACE GAS SUPPLY IS TURNED
OFF.
2. Locate the gas-supply stub inside the fi replace and remove
the cap, if attached.
CAUTION: When removing the cap, make sure the stub does
not turn, loosening the connection inside the wall.
3. Attach the nut end of the fl ex connector to the adapter
found on the valve or, if attached, on the regulator behind
the valve. Tighten securely.
4. Place the burner system in the fi replace. Center the burner
in the fi replace.
5. Be sure gas to the fi replace is off. Remove the adapter
that is loosely connected to the fl ex connector (coming off
of the burner system). Attach the adapter to the gas-supply
stub using a pipe compound resistant to all gasses. Tighten
securely. Then attach the open end of the fl ex connector to
the adapter. Tighten securely.
6. LEAK TEST: Turn on the fi replace gas supply, and test at
all connections for leaks using the appropriate soapy water
solution. If bubbles appear, a leak is present. Turn off the
gas and tighten at all connections. Repeat until no leaks
are present. If a leak persists, turn off the gas supply and
contact the local gas company or dealer. NEVER USE A
FLAME TO CHECK FOR LEAKS.
Turn off the gas supply prior to proceeding.
ATTACHING THE BURNER TO THE FLOOR
Two holes exist on the base of the burner assembly for securing
it to the fi replace fl oor in a mobile home, or if required by the
installation or inspector. Using the appropriate hardware for your
fi replace construction (not included); secure the burner system
into the fi replace fl oor (see Fig. 14-4).
Note: If you have a manufactured fi replace, check with the
manufacturer before drilling holes in the fl oor.
Burner
with
manual
valve
Fig. 14-3
Flex
connector
Large
adapter
Gas-supply
line
Flex
connector
Large
adapter
Gas-supply
line
ODS pilot
control
Flame
height
control
Burner with remote
series 12 valve
Manual
valve
control
knob
Fig. 14-1
Burner with
remote
series 15 valve
Flex
connector
ODS pilot
and
fl ame
control
knobs
Control
switch
Fig. 14-2
Adapter
Adapter
Large
adapter
Elbow adapter
Gas-supply