Owner`s manual

13
Note: To install the Real-Fyre
®
unvented gas log set, the fi replace must have a gas-supply line
that has been installed by a qualifi ed professional technician in accordance with all local
codes. Refer to the PARTS LIST when installing the unvented gas log set.
BE SURE THE GAS SUPPLY TO THE FIREPLACE IS TURNED OFF.
BEFORE PROCEEDING, CAREFULLY READ ALL OF THE IMPORTANT SAFETY
INFORMATION CONTAINED IN THIS OWNER’S MANUAL, INCLUDING:
A. PRE-INSTALLATION AND FIREPLACE PREPARATION SAFETY GUIDELINES.
B. VENTILATION AND CONFINED SPACE INFORMATION.
C. INSTALLATION SAFETY GUIDELINES.
CONNECTING THE GAS TO THE BURNER SYSTEM
Important: Be sure you have read and understand all safety precautions and warnings contained in
this manual.
Important: CHECK GAS TYPE (natural or L.P. gas). The gas supply must be the same as stated
on the gas log set rating plate. If the gas supply is different, DO NOT INSTALL.
Contact the dealer for immediate assistance.
Tools Required:
1. Adjustable open-ended wrench
2. Pliers
3. L.P. gas–resistant pipe compound or Tefl on tape
4. Soapy water solution & brush for leak
detection
5. Standard-head screwdriver
6. Manometer (recommended for checking gas
pressure)
INSTALLATION
WHEN USED AS A VENTED DECORATIVE APPLIANCE (PER ANSI Z21.60b-2004)
These gas logs may be installed as vented decorative log sets in compliance with ANSI Z21.60b-2004 and
National Fuel Gas Code, Section 6.6. The minimum permanent free opening of the fi replace chimney or chimney
damper must be met per the Chimney Vent Opening Table on pg 3 of this manual. Chimney damper must be
xed in a manner to maintain permanent free opening at all times. To accomplish this, install a screw or bolt
in the edge of the damper to prevent closing, or drill holes in the damper or remove the damper.
This appliance is for installation in a solid-fuel-burning fi replace (masonry fi replace or manufactured
replace) with a working fl ue and constructed of noncombustible material.