Owner`s manual

12
INSTALLATION - CONNECTING THE GAS TO THE BURNER SYSTEM
BEFORE PROCEEDING, CAREFULLY READ ALL OF THE IMPORTANT SAFETY INFORMATION
CONTAINED IN THIS OWNER’S MANUAL, INCLUDING:
A. Pre-Installation and Fireplace Preparation Safety Guidelines
B. Ventilation and Confi ned Space Information
C. Installation Safety Guidelines
1. Adjustable open-ended wrench
2. Pliers
3. L.P. gas resistant pipe compound or Tefl on tape
4. Soapy water solution & brush for leak detection
5. Flathead screwdriver
6. Manometer (recommended for checking gas
pressure)
Tools Required:
Note: To install your Real-Fyre
®
vent-free gas log set, your fi replace must have a gas supply line
that has been installed by a qualifi ed professional technician in accordance with all local
codes. Refer to the PARTS LIST when installing the vent-free gas log set.
IMPORTANT
Be sure you have read and understand all safety precautions and warnings
contained in this manual.
WARNING
Do not connect this appliance directly to a high pressure natural gas line or an unregulated L.P. gas tank.
CHECK GAS TYPE (natural or L.P.). The gas supply must be the same as stated on your gas log set
rating plate. If the gas supply is different, DO NOT INSTALL. Contact your dealer for immediate
assistance.
This appliance is for installation in a solid-fuel burning fi replace (masonry fi replace or manufactured
replace) with a working fl ue and constructed of noncombustible material.
WHEN USED AS A VENTED DECORATIVE APPLIANCE (PER ANSI Z21.60b-2004)
These gas logs may be installed as vented decorative log sets in compliance with ANSI Z21.60b-2004 and
National Fuel Gas Code, Section 6.6. The minimum permanent free opening of the fi replace chimney or chimney
damper must be met per the Chimney Vent Opening Table on pg 3 of this manual. Chimney damper must be
xed in a manner to maintain permanent free opening at all times. To accomplish this, install a screw or bolt
in the edge of the damper to prevent closing, or drill holes in the damper or remove the damper.