Owner`s manual

3
NO. L-F2-06807
REV 4 - 0705100745
FIREPLACE SIZE REQUIREMENTS AND BTU RATING
FIREPLACE SIZE REQUIREMENTS AND BTU RATING
INFORMATION
INFORMATION
The minimum size of FIREPLACE for installation
of this G9 unvented gas log set is:
BTU rating
Log
set
size
Width
Depth Height
High setting Low setting
Manual
valve
Millivolt
valve
Millivolt
valve
Manual
valve
Millivolt
valve
Manual
valve
20"
24" front
20" rear
31" front
22" rear
14" 18" 36,000 36,000 21,000 17,000
24"
29" front
20" rear
31" front
22" rear
14" 18" 36,000 36,000 21,000 17,000
30"
34" front
26" rear
40" front
29" rear
14" 18" 36,000 36,000 21,000 17,000
G9 SPECIFICATIONS AND REQUIREMENTS
APPROVED INSTALLATIONS
Subject to minimum fi replace size requirements
specifi ed below:
1. Solid-fuel-burning replaces;
A) Prefabricated fi replaces listed to UL-127
B) All other masonry fi replaces
2. Universal-listed vent-free fi replaces.
G9 Series vent-free gas log sets are available with a
variable fl ame-height control valve that can be used
with the optional remote transmitter and receiver.
A spark ignition system (piezo) allows the gas ODS pilot
to be lit without the use of matches, and permits the
operation of the appliance during a power outage.
This vent-free gas log set is equipped with an Oxygen
Depletion Sensor (ODS) safety pilot system. The
ODS pilot senses the amount of oxygen available in
the room and shuts the log set off before the oxygen
level drops below 18%. The ODS pilot can only be relit
when fresh air is available. This may require opening
a window or a door to another room or cracking
the damper open slightly.
This gas log set has been certifi ed to two standards:
UNVENTED ROOM HEATER-ANSI Z21.11.2-2007
VENTED DECORATIVE APPLIANCE-ANSI Z21.60b-2004
Check local or state codes to determine if vent-free
heaters are permitted in the locality before you install
this log set as a vent-free appliance. If not permitted,
you may install and operate this log set as a vented
appliance.
State or local codes may only allow operation of this
appliance in a vented confi guration. Check your state
or local codes.
Important: For safe operation and proper performance of this product and to comply with certifi cation, listings,
and building code acceptances, use ONLY Peterson Real-Fyre
®
controls, parts, and accessories
that have been specifi cally listed or certifi ed for use with this burner system. Use of other controls,
parts, or accessories is prohibited and will void all warranties, certifi cations, listings, and building
code approvals, and may cause property damage, personal injury, and loss of life.
Fireplace dimensions
Fig. 3-1
DEPTH
HEIGHT
FR ONT
WIDTH OPENING
Height
Depth
Rear
width
Front
width opening